Type A-P
Qmax=1250m3/h – Hmax=50m
APPLICATION
The A-P pumps are designed to handle chemical products of high temperature and pressure. Due to the robust design, apart from the basic application in chemical plants, the A-P pumps can be applied in any industry where hot or toxic fluids under high pressure are to be pumped, such as, for example, power plants or district heating plants. Due to the compliance with Atex directive the A-P pumps can operate in areas where hazard of explosion is present.
DESIGN
Single stage, horizontal, end suction pumps with own bearings classified as UMDP (upgraded medium duty pumps). The design is also in compliance with Atex directive. The A-P pumps are equipped with large seal chamber providing space to install any required mechanical seal configuration . If necessary the pumps can be equipped with heating or cooling jackets or with inducers to improve the suction properties. The design of the pumps of different sizes is unified – there are five standard bearings assemblies and seal chambers which can be combined with different wet ends. Such a unification reduces the quantity of spare parts to be stored and eases the maintenance.
MATERIALS OF CONSTRUCTION
A-P pumps are available in different material versions including stainless steel, stainless cast steel, duplex, superduplex and hastalloy. The materials of construction are selected individually for each application.
No. |
Part name |
No. |
Part name |
1 | Pump casing | 12 | Casing Sealing ring |
2 | Impeller | 13 | Impeller nut |
3 | Seal casing | 14 | Impeller washer |
4 | Shaft | 15 | Mechanical seal |
5 | Radial Thrust bearing cover | 16 | Expeller |
6 | Radial bearing | 17 | Labyrinth |
7 | Bearing housing | 18 | Oil filler |
8 | Thrust bearing | 19 | Casing support |
9 | Thrust Thrust bearing cover | 20 | Labyrinth |
10 | Toothed washer | 21 | Expeller |
11 | Bearing nut KM |
Pump type |
Dimensions [mm] |
|||||
Ds |
Dt |
L |
a |
H |
h |
|
3A16-P | 50 | 32 | 465 | 80 | 292 | 132 |
3A20-P | 465 | 80 | 340 | 160 | ||
3A25-P | 600 | 100 | 405 | 180 | ||
4A20-P | 65 | 40 | 485 | 100 | 340 | 160 |
4A25-P | 600 | 100 | 405 | 180 | ||
4A32-P | 625 | 125 | 450 | 200 | ||
5A16-P | 65 | 50 | 465 | 80 | 292 | 132 |
5A20-P | 80 | 50 | 485 | 100 | 360 | 160 |
5A25-P | 625 | 125 | 405 | 180 | ||
5A32-P | 625 | 125 | 505 | 225 | ||
6A16-P | 485 | 100 | 340 | 160 | ||
6A20-P | 100 | 65 | 600 | 100 | 405 | 180 |
6A25-P | 625 | 125 | 450 | 200 | ||
6A32-P | 655 | 125 | 505 | 225 | ||
8A16-P | 100 | 80 | 600 | 100 | 360 | 160 |
8A20-P | 125 | 80 | 625 | 125 | 430 | 180 |
8A25-P | 625 | 125 | 505 | 225 | ||
8A32-P | 655 | 125 | 565 | 250 | ||
10A20-P | 125 | 100 | 625 | 125 | 480 | 200 |
10A25-P | 670 | 140 | 505 | 225 | ||
10A32-P | 670 | 140 | 565 | 250 | ||
12A25-P | 150 | 125 | 670 | 140 | 605 | 250 |
12A32-P | 670 | 140 | 635 | 280 | ||
15A25-P | 200 | 150 | 690 | 160 | 655 | 280 |
15A32-P | 830 | 160 | 715 | 315 | ||
15A40-P | 830 | 160 | 765 | 315 | ||
20A25-P | 200 | 200 | 850 | 180 | 780 | 355 |
20A32-P | 250 | 200 | 870 | 200 | 805 | 355 |
20A40-P | 870 | 200 | 855 | 355 | ||
20A50-P | 900 | 200 | 990 | 425 | ||
25A40-P | 300 | 250 | 900 | 200 | 1025 | 425 |
25A50-P | 250 | 250 | 900 | 200 | 1145 | 475 |
30A40-P | 350 | 300 | 950 | 250 | 1105 | 475 |
Pump type |
Rotation speed |
Rotation speed |
Weight |
||||
Capacity |
Head |
Shaft power |
Capacity |
Head |
Shaft power |
||
3A16-P | 12,5 | 32 | 2 | 6,3 | 8 | 0,3 | 65 |
3A20-P | 12,5 | 50 | 3,8 | 6,3 | 12,5 | 0,6 | 75 |
3A25-P | 12,5 | 80 | 7,8 | 6,3 | 20 | 1,1 | 120 |
4A20-P | 25 | 50 | 5,7 | 12,5 | 12,5 | 0,8 | 80 |
4A25-P | 25 | 80 | 11,6 | 12,5 | 20 | 1,6 | 122 |
4A32-P | 25 | 128 | 23,6 | 12,5 | 32 | 3,4 | 153 |
5A16-P | 25 | 32 | 3,8 | 12,5 | 8 | 0,5 | 70 |
5A20-P | 50 | 50 | 9,2 | 25 | 12,5 | 1,3 | 82 |
5A25-P | 50 | 80 | 19,1 | 25 | 20 | 2,4 | 124 |
5A32-P | 50 | 128 | 33,5 | 25 | 32 | 4,5 | 158 |
6A16-P | 50 | 32 | 6,0 | 25 | 8 | 0,8 | 73 |
6A20-P | 100 | 50 | 17,7 | 50 | 12,5 | 2,4 | 110 |
6A25-P | 100 | 80 | 32,5 | 50 | 20 | 4,4 | 138 |
6A32-P | 100 | 128 | 53,7 | 50 | 32 | 7,3 | 190 |
8A16-P | 100 | 32 | 11,7 | 50 | 8 | 1,7 | 98 |
8A20-P | 160 | 50 | 27,2 | 80 | 12,5 | 3,7 | 119 |
8A25-P | 160 | 80 | 45,9 | 80 | 20 | 5,8 | 142 |
8A32-P | 160 | 128 | 79,7 | 80 | 32 | 10,6 | 196 |
10A20-P | 250 | 50 | 42,6 | 125 | 12,5 | 5,5 | 138 |
10A25-P | 250 | 80 | 69,9 | 125 | 20 | 8,7 | 204 |
10A32-P | 250 | 128 | 118,6 | 125 | 32 | 15,1 | 212 |
12A25-P | 400 | 80 | 111,8 | 200 | 20 | 13,1 | 218 |
12A32-P | 400 | 128 | 176,6 | 200 | 32 | 22,6 | 230 |
15A25-P | – | – | – | 315 | 20 | 21,5 | 268 |
15A32-P | – | – | – | 315 | 32 | 33,5 | 310 |
15A40-P | – | – | – | 315 | 50 | 51,7 | 385 |
20A25-P | – | – | – | 500 | 20 | 34,5 | 342 |
20A32-P | – | – | – | 500 | 32 | 52,5 | 392 |
20A40-P | – | – | – | 500 | 50 | 82,1 | 422 |
20A50-P | – | – | – | 500 | 80 | 145,3 | 450 |
25A40-P | – | – | – | 800 | 50 | 129,8 | 465 |
25A50-P | – | – | – | 800 | 80 | 235,7 | 495 |
30A40-P | – | – | – | 1250 | 50 | 212,9 | 580 |
The parameters are specified for clean water of density ρ=1000 kg/m3 and temperature T=15°C